4.5 AC Main Distribution
The AC panel is located in the head compartment. The following are descriptions of the AC panel equipment
and the breakers that protect the accessories:
AC Volt Meter
Indicates the voltage supplied to the panel.
Galvanic Isolator Monitor
The monitor for the galvanic isolator is mounted in the AC breaker panel. The monitor continuously tests and
displays the condition of polarity, ground wire continuity and galvanic isolator functioning. Should the
reverse polarity indicator light, a relay attached to the main breaker will automatically turn the main breaker
off. If reverse polarity occurs, immediately turn off all cabin AC breakers and dockside outlet breakers and
notify a qualified electrician to check the dockside wiring. Refer to the galvanic isolator monitor owner's
manual.
THE CONTINUOUS TESTING OF THE SHORE POWER CONNECTION BY THE GALVANIC ISO-
LATOR MONITOR PREVENTS THE USE OF A 15 OR 20 AMP SHORESIDE CONVENIENCE
OUTLET EQUIPPED WITH A GROUND FAULT CIRCUIT INTERRUPTER (GFCI). TO ENSURE
AGAINST NUISANCE TRIPPING OF BREAKERS OR GFCI'S ONLY A MARINE 30 AMP TWIST
LOCK SHORESIDE RECEPTACLE IS TO BE USED.
AC Main Breaker
Protects the general distribution network. This breaker is very sensitive. The resulting power surge that
occurs when connecting the dockside cord may cause the main breaker to trip. To avoid this surge, always
turn the main breaker to the “OFF” position before plugging or unplugging the shore power cord.
Battery Charger
Supplies electrical current directly to the battery charger which is accessed through the starboard access
hatch in the storage compartment in the console.
Outlets
Supply electrical current to the ground fault interrupter (GFI) electrical outlet.
Note: All AC electrical outlets are provided with ground fault interrupters to protect against electric shock.
These outlets should be tested periodically to ensure proper operation by pressing the test/reset buttons in the
center of the face plate. GFI outlets do not protect against short circuits and overloads. This is done by the
outlet breaker on the AC panel.
Accessory
Reserved for additional AC equipment.
GFI OUTLETS DO NOT PROVIDE 100% PROTECTION FROM ELECTRIC SHOCK. EVEN
THOUGH GROUND FAULT INTERRUPTERS PROVIDE PROTECTION BY REDUCING EXPOSURE
TIME FROM LINE TO GROUND SHOCK HAZARDS, IT IS STILL POSSIBLE TO RECEIVE AN
ELECTRIC SHOCK FROM DEFECTIVE APPLIANCES OR POWER TOOLS AND MISUSED ELEC-
TRICAL EQUIPMENT.